HM Water Pressure Systems with Torrium2 HM90-13T
Brand: Davey
SKU: HM90-13T
Was $2,550.00
$1,970.00
Availability: Available
| Torrium2 Intelligent Controller | Adaptive controller continuously monitors water demand, eliminates pump cycling and maintains steady, consistent pressure automatically |
|---|---|
| High Flow & High Pressure | Nominal 90 lpm flow at 480 kPa with a maximum pump pressure of 680 kPa — the highest-pressure model in the HM90 range |
| Loss of Prime Protection | Torrium2 detects loss of prime and shuts the pump down immediately to prevent internal damage |
| Over Temperature Cut-Out | Automatically stops the pump if operating temperature exceeds safe limits, protecting the motor and pump from damage |
| All Stainless Steel Hydraulics | 304 stainless steel casing, impellers and stages with 316L stainless steel pump shaft for outstanding corrosion and wear resistance |
| Suitable for High Water Temperatures | Robust stainless steel construction and EPDM seals handle elevated water temperatures with ease |
| High Efficiency Impellers | Optimised impeller profile with thick self-centring neck rings delivers maximum output with reduced power consumption and low noise |
| Compact Axial Suction Design | Horizontal layout with axial suction and vertical discharge minimises installation footprint and simplifies pipework |
| Air Purging Valve | Built-in air purging and stage porting simplifies priming and reduces susceptibility to air leaks for improved dependability |
| Direct Drive Motor Shaft | Impellers mounted directly on the extended motor shaft maximise efficiency per stage and extend the service life of both pump and motor |
| 8-Point Casing Seal | Pump casing secured to motor bracket at 8 points with O-ring seal for superior leak resistance and longer service life |
| Thermal Overload Protection | Built-in automatic reset thermal overload protects the motor against damage from overheating or jamming |
| Surge Protection | Varistor surge protection built into the Torrium2 controller safeguards against electrical damage |
| Model | HM90-13T |
|---|---|
| Nominal Flow Rate | 90 lpm |
| Nominal Operating Pressure | 480 kPa |
| Maximum Pump Pressure | 680 kPa |
| Tank Air Pre-charge | 475 kPa |
| Maximum Continuous Flow | 200 lpm |
| Maximum Operating Pressure | 700 kPa* |
| Cut-in Pressure Range | 80% of pump shut-off head |
| Supply Voltage | 230V ±10% / Single Phase / 50Hz |
| Motor Speed | 2,900 RPM |
| Suction Port | 1¼" BSP Female |
| Discharge Port | 1" BSP Male |
| Dimensions (L×W×H) | 503 × 124 × 175 mm |